How to seal a leaking radiator valve gland

5 min readPublished

A damp patch under a radiator valve looks alarming and usually is not. If the water is appearing where the valve head meets its body, on the little shaft you turn, the seal around that shaft has given up. That is a leaking radiator valve gland, and it is one of the few heating repairs where the fix costs almost nothing and takes about twenty minutes. It happens most often to valves that have sat untouched all summer and are turned for the first time in October, because the packing inside has dried and compressed.

Make sure it really is the gland

Dry the whole valve and the pipe below it with kitchen roll, then wrap a strip of dry paper loosely round the body and leave it half an hour. Where the paper darkens tells you the truth. Water on the spindle, under the head, means the packing. Water at the nut where the valve joins the copper pipe means the compression joint and its olive. Water at the union where the valve screws into the radiator itself means that connection or the radiator tail. Only the first one is a gland problem, and treating a compression leak as a gland leak wastes an afternoon. Our guide on a leaking radiator valve walks through the other two.

One more clue: a gland weep normally appears or worsens while the valve is being turned and settles to a slow bead afterwards. A joint leak drips at the same rate whatever you do to the head.

Turn the water off first

You can do this without draining the system, but you must isolate the radiator at both ends. Close the valve you are working on by turning it fully clockwise, or by winding a thermostatic head down to its off position. Then go to the other end of the radiator, pull the cap off the lockshield valve and close it with a small spanner or pliers, counting the exact number of turns as you go, because you have to open it by the same amount afterwards or that radiator will never heat properly again.

  1. Lay old towels under the valve and keep a bowl and a jug within reach.
  2. Close the control valve fully clockwise, and close the lockshield at the far end, counting the turns.
  3. Slacken the bleed screw at the top of the radiator a fraction to release pressure, then nip it back up.
  4. Have a cloth ready. There will be a little water in the valve body even with both ends closed.

Try a quarter turn before anything else

The gland nut is the small hexagonal nut immediately beneath the head or handwheel, sitting around the spindle. It is not the large nut lower down that grips the pipe. Pull the head off first: on a manual valve it is usually a small screw in the top, and on a thermostatic head it is a ring you unscrew by hand once the head is turned to its highest setting. With the gland nut exposed, hold the valve body steady with one spanner and turn the gland nut clockwise with another, no more than a quarter of a turn.

Refit the head, open the valve, and watch. Roughly half the time that quarter turn compresses the old packing enough to seal it and you are finished. Resist the urge to keep going. Overtightening does not squeeze harder, it distorts the packing, makes the valve stiff to turn, and on an old brass valve can crack the body or disturb the olive on the joint below, turning a five minute job into a plumbing repair.

Re-pack the gland with PTFE tape

If the weep survives that quarter turn, the packing is finished and needs replacing. With the radiator still isolated, undo the gland nut fully and lift it up the spindle. Underneath you will find the remains of the original packing, often a grey or black fibrous ring, sometimes a rubber O ring. Pick it out with a small screwdriver or a scriber and wipe the recess clean.

  1. Tear off about 200mm of PTFE tape and twist it along its length into a thin string.
  2. Wind that string clockwise into the recess around the spindle, three or four turns, packing it down with a small screwdriver as you go.
  3. Slide the gland nut back down and do it up finger tight, then a further quarter to half turn with a spanner.
  4. Refit the head, open the control valve, then reopen the lockshield by the exact number of turns you counted.
  5. Work the valve fully open and closed twice and watch the spindle for a full minute.

Where the original was an O ring rather than fibre, a replacement O ring of the same size is a neater repair than tape, and most plumbers merchants sell mixed packs for a couple of pounds. Some people use a smear of silicone grease on the spindle to keep the new packing supple, which does no harm. A leaking radiator valve gland that has been re-packed carefully should then stay dry for years, so if yours weeps again within a season, look past the packing at the valve itself.

Finish the job properly

Once the leak has stopped, dry everything and check again the next morning, and again after the heating has run a full cycle, because heat expands brass and a seal that holds cold can weep hot. Top the boiler pressure back up if the gauge has dropped, as our guide on boiler pressure too low explains. If the radiator now runs cold at the bottom or refuses to warm at all, the lockshield has not gone back to its old setting, and a small adjustment either way usually restores the balance.

When to call a heating engineer

Call someone if the valve body itself is weeping or green with corrosion, if the spindle is bent or will not turn, if the leak returns within days of a fresh re-pack, or if either compression joint starts dripping while you work. A tired valve is cheap to replace and a good heating engineer will swap it, often for a thermostatic one, in under an hour. Also call rather than experiment if your system is unvented or sealed and you are not sure how to refill and re-pressurise it, or if the pressure keeps falling afterwards, which points at a leak somewhere else and is covered in our guide on a boiler losing pressure overnight.

Common questions

Can I fix a leaking radiator valve gland without draining the system?

Yes, in almost every case. Closing the control valve at one end and the lockshield at the other isolates the radiator, so only the small amount of water sitting in the valve body escapes. Count the lockshield turns so you can reopen it to the same position.

Why does my radiator valve leak only when I turn it?

The packing around the spindle has hardened and no longer grips as the shaft moves. Turning the valve breaks whatever seal the dried packing was still making, which is why leaks so often start on the first cold day after a summer of the heating being off.

How tight should the gland nut be?

Finger tight plus about a quarter turn with a spanner is the target. If it needs more than that to seal, the packing itself is worn out and should be replaced rather than crushed harder, because overtightening stiffens the valve and can damage the brass.

leaking radiator valve glandradiator valve leaking from spindleradiator valve packing nuthow to repack a radiator valve