If you keep finding the pressure gauge near zero at breakfast, you are not imagining it: a boiler losing pressure overnight is one of the most common heating faults in British homes. Sealed systems are meant to hold a steady 1 to 1.5 bar when cold. A slow overnight drop means water is escaping somewhere, or the part designed to absorb pressure swings has failed. Topping up through the filling loop gets the heating going, but it is a symptom, not a fix, and constantly adding fresh water accelerates corrosion inside the system.
How fast is it dropping?
Before anything else, take two readings: pressure when the system is cold at night, and again cold in the morning. A drop of a whole bar overnight points to a real water leak. A gauge that swings high when the heating runs and then settles low suggests an expansion vessel problem instead. Write the numbers down for a few days; an engineer will love you for it.
The four usual causes
- A weep somewhere on the system: a radiator valve, a compression joint under a floor, or a corroded radiator seam. Check every radiator and visible pipe run for damp, salt-like crust or rust stains.
- A flat expansion vessel. The vessel contains a cushion of air behind a diaphragm; when it loses its charge, pressure spikes as the water heats and the safety valve dumps the excess outside. The classic sign is pressure that is fine by day and gone by morning.
- A passing pressure relief valve. Look at the small copper discharge pipe that exits through the outside wall near the boiler. If it drips, or the ground below is stained green, the valve is letting water out.
- A leak inside the boiler itself, often the heat exchanger or an internal fitting. You may see dampness under the casing or hear a faint hiss.
What you can safely do yourself
Walk the whole system with a torch and dry tissue: wipe every valve, joint and radiator seam and look for wet spots. Check ceilings below pipe runs for faint brown rings. Feel the relief valve discharge pipe outside after the heating has run hot. Repressurise through the filling loop to the mark your manual gives, usually 1 to 1.5 bar cold, and remember to close both filling loop valves fully afterwards, because a passing filling loop quietly overpressurises the system and causes its own faults. Fixing a visible radiator valve leak is fair DIY territory, and we cover that in our leaking radiator valve guide.
What needs an engineer
Anything inside the boiler casing is not a DIY job. On a gas boiler, work on the appliance must be done by a Gas Safe registered engineer. Recharging or replacing an expansion vessel, swapping a pressure relief valve and tracing hidden leaks under floors are all routine visits. If the leak cannot be found by eye, engineers use system leak sealer for tiny weeps or a pressure test to isolate the losing section. Persistent pressure loss that is ignored eventually means limescale, corrosion and a locked-out boiler on the coldest morning of the year, so it is worth solving properly.
Common questions
Is it safe to keep topping up a boiler that loses pressure?
For a few days, yes. Long term, no: every top-up brings in fresh oxygenated water that corrodes radiators and sludges the system. Find and fix the cause.
What pressure should my boiler be at?
Most sealed systems want 1 to 1.5 bar when cold. Check the manual, or the label on the drop-down panel that carries the gauge and filling loop, for the exact figure. That panel is the part designed for you to open; the casing itself is not. Above about 2.5 bar cold is too high.
Why does the pressure only drop when the heating is on?
Heated water expands and raises pressure. If the expansion vessel cannot absorb that swing, the relief valve discharges water outside, so pressure reads low once everything cools. That pattern usually means the vessel needs recharging.
Can a boiler lose pressure without any leak?
Genuinely sealed systems do not lose pressure by magic. If no leak is visible, the water is going out through the relief valve discharge pipe, through a failed internal part, or into a hidden pipe run under floors.