You noticed the pressure gauge had dropped, opened the filling loop, brought it back up to the green band, and now the system sounds like a kettle full of pebbles. Radiators gurgle, one bangs when the heating fires, and the ones upstairs are hot at the bottom and stone cold across the top. Nothing has gone wrong. Fresh mains water carries dissolved gas, and opening the loop pushes a slug of air into pipework that was previously full. Clearing air in radiators after a top up is a twenty minute job, and doing it in the right order saves you doing it twice.
Why refilling always brings air with it
A sealed heating system is a closed loop that is meant to stay full. When you add water through the filling loop you also add whatever gas that water is holding, plus any air already sitting in the loop hose itself. As the system heats, that gas comes out of solution and rises, collecting at the highest points it can reach, which is the top of each radiator and the top of the pipe runs. The noise you hear is water being forced past those pockets. It is harmless in the short term, but leaving it costs you heat, wastes gas, and lets oxygen sit against steel where it will slowly corrode.
A cold strip along the top of a radiator is the classic sign. If yours is cold along the bottom instead, that is sludge rather than air, and our guide on why a radiator is cold at the bottom covers it.
Bleed in the right order
Order matters because air moves upward and outward from the pump. Work from the lowest and nearest radiator to the highest and furthest, which in most houses means the whole ground floor first, then upstairs, finishing at the radiator furthest from the boiler. Bleeding the top of the house first simply drags more air up from below and you end up going round twice.
- Turn the heating off at the programmer and let the system stand for fifteen to twenty minutes so it is not hot and the air can gather at the top of each radiator.
- Start downstairs at the radiator nearest the boiler. Hold a cloth and a small container under the bleed valve at the top corner.
- Turn the bleed key anticlockwise a quarter to half turn only. Let the hiss run until water appears steadily rather than spitting, then close it snugly. Do not over tighten.
- Work along the ground floor, then go upstairs and repeat, finishing at the furthest radiator from the boiler.
- Check the pressure gauge. Bleeding releases pressure, so it will have fallen.
- Top the system back up to the pressure in the boiler manual, usually somewhere between 1.0 and 1.5 bar cold, then close both filling loop valves and disconnect the hose if yours is removable.
- Fire the heating and let it run for half an hour, then feel every radiator top to bottom. Any that are still cold at the top get one more bleed once the system has cooled.
Two or three rounds over a couple of days is normal after a big refill, because gas keeps coming out of solution as the water is heated and stirred. Our guide on how to bleed a radiator covers the technique itself in more detail if you have never used a bleed key.
Watch the pressure while you do it
The mistake that turns this into a longer job is ignoring the gauge. Every bleed lets water and pressure out, so a system bled from twelve radiators can easily drop below the point where the boiler will fire, and some units then lock out entirely. Equally, do not overfill in anticipation: above roughly 2.5 bar cold the pressure relief valve will dump water outside and you will be back to a low reading tomorrow with a puddle to explain. Fill in small bursts with the gauge in sight, and remember the needle rises when everything is hot and falls when it cools, so judge it cold.
When the air keeps coming back
One clear out is normal. Finding air in radiators again a fortnight later is not, and it points at something drawing gas into a system that should be sealed. The common causes are a slow leak somewhere on the pipework or a weeping valve gland, which lets water out and air in as the system cools and contracts. Others are a failed automatic air vent on the boiler or in the loft, an expansion vessel that has lost its charge so pressure swings wildly, a pump running too fast and pulling air past a joint, or corrosion inside old steel radiators generating hydrogen. There is a rough field test for the last one: hydrogen from corrosion tends to come out as a small, sharp release from radiators that also run sludgy, whereas ordinary trapped air is a longer softer hiss.
Persistent air alongside a pressure gauge that keeps sinking almost always means a leak. Look under radiator valves, at any visible pipework, at the boiler case, and at the overflow pipe outside the house. Our guide on a boiler losing pressure overnight walks through finding it.
When to call a heating engineer
Call someone if the pressure will not hold after a proper bleed and refill, if you cannot find where the water is going, if the system bangs loudly rather than gurgles once the air is out, if a bleed valve is seized or snaps, or if what comes out of the radiators is thick and black rather than clear, which means the water needs a proper power flush and an inhibitor dose rather than another bleed. Call straight away, and do not keep refilling, if the pressure relief pipe outside is discharging continuously or if you smell gas at any point.
Common questions
How long after topping up the boiler should I bleed the radiators?
Let the system stand for at least fifteen minutes with the heating off so the air has time to collect at the top of each radiator. Many people top up, run the heating for an hour, then bleed once it has cooled again, which clears more in a single pass.
Which radiator should I bleed first?
The lowest and closest to the boiler, then work outward and upward, finishing with the radiator that is highest and furthest away. Air travels up and away from the pump, so bleeding upstairs first just pulls more air up from the ground floor.
Is it normal to lose pressure after bleeding radiators?
Yes. Every bleed releases water as well as air, so the gauge will read lower afterwards. Top the system back to the figure in your boiler manual, usually around 1.0 to 1.5 bar when cold, and check it again the next morning.