A towel radiator that is hot at the bottom and stone cold across the top rungs is not broken: it is full of air. Ladder rails are usually the tallest thing on the heating circuit, often upstairs, so every bubble of air working around the system eventually rises into them and sits at the top, blocking hot water from filling the upper rungs. To bleed a towel radiator you release that air through the small valve at the top, and the whole job takes a couple of minutes.
What you need
- A radiator bleed key from any DIY or hardware shop, though some modern valves take a flat-blade screwdriver.
- A cloth and a small cup or jug to catch the dribble of water.
- A look at the boiler's pressure gauge first, if you have a combi or sealed system: note the reading so you can top up afterwards.
Bleed it in five steps
- Turn the heating off and let the rail cool. Bleeding with the pump running can drag more air in, and the escaping water can be scalding.
- Find the bleed valve: a small square-ended plug at the top of the rail, on the side or the top face of one upright.
- Hold the cloth and cup under the valve and turn the key anticlockwise about half a turn. You will hear a hiss as the air escapes.
- Wait as the hiss fades. The moment water spurts or dribbles steadily, the air is out: close the valve clockwise, snug but not forced.
- Wipe up, switch the heating back on, and feel the top rungs after ten minutes. They should heat evenly to the top.
Check the boiler pressure afterwards
On a combi or any sealed system, the air you released was holding pressure, so the gauge will have dropped a little. Repressurise through the filling loop to your system's normal cold reading, typically between 1 and 1.5 bar, and close the loop valves fully afterwards. Open-vented systems with a tank in the loft top themselves up automatically. If the rail is on an electric or dual-fuel circuit, switch the element off and let it cool before bleeding, and never run the element with the rail partly empty, because heating elements fail quickly when not fully submerged.
If it keeps needing bleeding
Bleeding once a season is normal life at the top of a heating circuit. Needing it every week is a symptom: air is entering the system through a weeping joint or a failing pump seal, or hydrogen is being generated by corrosion inside radiators, a sign the inhibitor has run out. A rail that stays cold even after bleeding usually has a valve problem instead: check both valves at the base are open, and if one is a thermostatic head, make sure its pin has not stuck. Persistent cold patches at the bottom of radiators rather than the top point to sludge, which is a different fault, covered in our guide on why a radiator is cold at the bottom. A plumber or heating engineer can find an air leak, re-dose inhibitor and get the system holding its balance again.
Common questions
Why is my towel radiator cold at the top but hot at the bottom?
Trapped air. Air rises to the highest point of the circuit, which is usually the towel rail, and sits in the top rungs where hot water cannot reach. Bleeding releases it.
Do I turn the heating off before bleeding a towel radiator?
Yes. With the pump running you can pull more air into the system, and the water inside can be hot enough to scald. Let it cool, bleed, then switch back on.
How often should a towel radiator need bleeding?
Once or twice a year is normal. If it needs bleeding every few weeks, air or gas is getting into the system from somewhere, and that cause is worth finding rather than managing.