How to Bleed a Towel Warmer That Won't Heat Up

2 min readUpdated

A towel warmer, or towel warmer as it is usually sold here, that runs hot at the bottom and cold across the top rungs isn't broken; it's filled with air. Ladder rails are typically the tallest component in the heating system, often located upstairs, so air bubbles rise into them, blocking hot water from reaching the upper rungs. Bleeding a towel warmer involves releasing that air through a valve at the top, and the entire process takes just a few minutes.

What You Need

Bleed It in Five Steps

  1. Turn off the heat and let the radiator cool. Bleeding with the system running can introduce more air, and the escaping water can be hot enough to burn.
  2. Locate the bleed valve: a small square-ended plug at the top of the radiator, on the side or top of one upright.
  3. Hold the cloth and cup under the valve and turn the key counterclockwise about half a turn. You'll hear a hiss as the air escapes.
  4. Wait until the hissing fades. As soon as water starts to spurt or dribble steadily, the air is out: close the valve clockwise, snug but not overly tight.
  5. Wipe up, turn the heat back on, and check the top rungs after ten minutes. They should heat evenly to the top.

Check the Boiler Pressure Afterward

In any sealed system, the air you released was holding pressure, so the gauge will have dropped slightly. Repressurize through the make-up water valve to your system's normal cold reading, typically between 15 and 22 psi, and close it fully afterward. Systems fitted with an automatic feed valve top themselves back up without you doing anything. If the radiator is on an electric or dual-fuel circuit, turn off the element and let it cool before bleeding, and never run the element with the radiator partly empty, as heating elements can fail quickly if not fully submerged.

If It Keeps Needing Bleeding

Bleeding once a season is normal for the highest point in a heating system. Needing it weekly indicates a problem: air may be entering through a leaking joint or a faulty pump seal, or hydrogen could be generated by corrosion inside radiators, suggesting the corrosion inhibitor has depleted. A radiator that remains cold even after bleeding likely has a valve issue: ensure both valves at the base are open, and if one has a thermostatic head, check that its pin isn't stuck. Persistent cold spots at the bottom of radiators rather than the top suggest sludge, which is a different issue, covered in our guide on why a radiator is cold at the bottom. A licensed heating contractor can find an air leak, replenish the corrosion inhibitor, and rebalance the system.

Common questions

Why is my towel warmer cold at the top but hot at the bottom?

Trapped air. Air rises to the highest point of the system, usually the towel warmer, and sits in the top rungs where hot water cannot reach. Bleeding releases it.

Do I turn the heat off before bleeding a towel warmer?

Yes. With the system running, you can introduce more air, and the water inside can be hot enough to burn. Let it cool, bleed, then turn it back on.

How often should a towel warmer need bleeding?

Once or twice a year is normal. If it needs bleeding every few weeks, air or gas is entering the system from somewhere, and that cause should be addressed rather than managed.