Guides › DIY & maintenance

How to fix a leaking radiator valve

2 min readPublished

A leaking radiator valve rarely announces itself with a flood. More often you spot a rusty ring on the floor, a damp patch on the carpet, or a slow drip you can only hear at night. The fix depends entirely on where the water is escaping, so the first job is to dry everything with kitchen roll and watch closely to see exactly where the next bead of water forms.

Find where the valve is leaking

There are three usual suspects. The gland is the packing around the valve spindle, under the plastic head or handwheel. The union nut is the large nut connecting the valve to the radiator tail. And occasionally the valve body itself has cracked or corroded, which is rarer but more serious.

Fixing a leaking gland

This is the most common leak and the easiest cure. Pull off the plastic head, then gently snug the small gland nut around the spindle a quarter turn clockwise with a spanner. Do not force it. If the drip continues, undo the gland nut, wind a few turns of PTFE tape down into the spindle recess, and tighten it back up. That repacks the seal and cures most weeping glands for years.

Fixing a leak at the union nut

First try tightening the union nut a fraction, holding the valve body steady with a second spanner so you do not twist the pipework. If it still drips, the olive inside the joint is no longer sealing. Curing that properly means draining the radiator: close the valve and the lockshield at the other end, counting the turns on the lockshield so you can reset it, then catch the water in a tray as you crack the union open. Wrap PTFE tape around the face of the olive, remake the joint, and reopen both valves.

If the valve body is leaking

A cracked or corroded valve body cannot be patched and the valve needs replacing. On a sealed combi system you will lose pressure as soon as the circuit is opened, and the system must be repressurised afterwards, typically to between 1 and 1.5 bar. If you are not confident isolating and draining, this is a sensible job to hand to a plumber or heating engineer. It is quick work for a professional, and worth pairing with a thermostatic radiator valve upgrade while the system is drained.

Stop the damage while you wait

Put a container under the drip and lift rugs and furniture clear. If the leak is more than a drip, close both valves on that radiator to isolate it from the rest of the system. The heating can usually stay on for the rest of the house. Keep an eye on your boiler's pressure gauge, because a persistent leaking radiator valve slowly drains a sealed system and the boiler may lock out when pressure falls too low.

Common questions

Can I fix a leaking radiator valve without draining the system?

Often, yes. Gland leaks are fixed with the water in place, and a union nut can sometimes be nipped up dry. Replacing the olive or the whole valve means draining at least that radiator.

Is a leaking radiator valve an emergency?

A slow drip is not, but do not ignore it: it damages floors and slowly drops the pressure in a sealed heating system. Isolate the radiator by closing both valves and book a repair.

How much does a plumber charge to replace a radiator valve?

It is usually under an hour of labour plus a modest part cost. Many people have a thermostatic valve fitted at the same time, since the draining work is already done.

leaking radiator valveradiator valve drippingradiator leaking at valvegland nut leak

Describe your job and a verified local tradesperson comes back with a priced quote you can accept online.

Get a real quote →

Planning a job at home? Design the room, save your ideas and get quotes in the FixTrade app.

See the app →