A leaking radiator valve rarely causes a flood. More often, you might notice a rusty ring on the floor, a wet patch on the carpet, or a slow drip you can only hear at night. The fix depends entirely on where the water is escaping, so the first step is to dry everything with paper towels and watch closely to see exactly where the next bead of water forms.
Find Where the Valve Is Leaking
There are three usual suspects. The gland is the packing around the valve spindle, under the plastic head or handwheel. The union nut is the large nut connecting the valve to the radiator tail. Occasionally, the valve body itself has cracked or corroded, which is rarer but more serious.
- Water weeping from under the valve head or around the spindle points to the gland.
- Water forming on the big nut between valve and radiator points to the union joint.
- Water seeping from the casting itself, with no joint nearby, means the valve body has failed and needs replacing.
Fixing a Leaking Gland
This is the most common leak and the easiest to fix. Pull off the plastic head, then gently tighten the small gland nut around the spindle a quarter turn clockwise with a wrench. Do not force it. If the drip continues, undo the gland nut, wind a few turns of PTFE tape down into the spindle recess, and tighten it back up. That repacks the seal and cures most weeping glands for years.
Fixing a Leak at the Union Nut
First, try tightening the union nut a fraction, holding the valve body steady with a second wrench so you do not twist the piping. If it still drips, the ferrule inside the joint is no longer sealing. Fixing that properly means draining the radiator: close the valve and the shutoff or balancing valve at the other end, counting the turns on the shutoff or balancing valve so you can reset it, then catch the water in a tray as you open the union. Wrap PTFE tape around the face of the ferrule, remake the joint, and reopen both valves.
If the Valve Body Is Leaking
A cracked or corroded valve body cannot be patched, and the valve needs replacing. On a sealed system, you will lose pressure as soon as the circuit is opened, and the system must be repressurized afterward, typically to between 15 and 22 psi. If you are not confident isolating and draining, this is a sensible job to hand to a plumber or heating contractor. It is quick work for a professional and worth pairing with a thermostatic radiator valve upgrade while the system is drained.
Stop the Damage While You Wait
Place a container under the drip and move rugs and furniture clear. If the leak is more than a drip, close both valves on that radiator to isolate it from the rest of the system. The heating can usually stay on for the rest of the house. Keep an eye on your boiler's pressure gauge, because a persistent leaking radiator valve slowly drains a sealed system and the boiler may shut off when pressure falls too low.
Common questions
Can I fix a leaking radiator valve without draining the system?
Often, yes. Gland leaks can be fixed with the water in place, and a union nut can sometimes be tightened dry. Replacing the ferrule or the whole valve means draining at least that radiator.
Is a leaking radiator valve an emergency?
A slow drip is not an emergency, but do not ignore it: it damages floors and slowly drops the pressure in a sealed heating system. Isolate the radiator by closing both valves and schedule a repair.
How much does a plumber charge to replace a radiator valve?
It's usually under an hour of labor plus a modest part cost. Many people have a thermostatic valve fitted at the same time, since the draining work is already done.