Most people assume an outdoor unit on the back wall needs the council's blessing. Since 2025 that is often not the case in England, but there is one detail in the rules that catches people out. Here is how planning permission for air conditioning works for a house, and the separate question of who is allowed to fit it.
Planning permission for air conditioning in England
A modern split air conditioning system is, technically, an air-to-air heat pump. On 29 May 2025 an amendment to the permitted development rules in England brought air-to-air heat pumps into the same rights that air-to-water heat pumps already had. That means many homes can fit one without applying, as long as the installation meets the conditions in the legislation. The main ones are:
- The unit must meet the MCS planning standard, which is mainly a noise calculation at your neighbour's nearest window
- Up to two units on a detached house, one on a semi, terrace or block of flats
- The outdoor unit must be no bigger than 1.5 cubic metres on a house
- Not on a pitched roof, and not within a metre of the edge of a flat roof
- Not on a wall facing a road above ground-floor level
- It should be sited to keep its effect on the look of the house and on neighbours to a minimum
The cooling-only catch
This is the part that surprises people. The legislation says a unit fitted under these rights must not be used solely for cooling. A reversible system that heats in winter and cools in summer fits the rules. A cooling-only unit does not, so it falls back on a normal planning application. Almost every wall-mounted split sold for homes today can heat as well as cool, so in practice this mostly matters if you are offered an older or cheaper cooling-only model.
When you will need to ask the council
- Your home is listed, or the unit would go in the grounds of a listed building
- You are in a conservation area and the unit would face a road
- Your council has removed permitted development rights with an Article 4 direction
- You live in a flat and want a unit on a shared wall, where the freeholder's consent is needed too
- You live in Wales, Scotland or Northern Ireland, which each have their own rules
If you are unsure, the Planning Portal explains the rules, and you can apply for a lawful development certificate for written confirmation.
Why the engineer needs F-gas certification
Planning is about where the unit goes. Who fits it is a separate law. A split system contains refrigerant, a fluorinated gas, and in Great Britain anyone who installs, services or recovers it must hold an F-gas qualification. Their company must also hold F-gas certification from an approved body, and this applies to sole traders too. Ask any installer for the company certificate number before work starts. Units sold with pre-filled quick connectors still need a qualified person to connect them properly.
The electrical side matters as well. A new dedicated circuit is notifiable work under Part P of the Building Regulations in England and Wales, so it needs a registered electrician or a building control notice, and you should get a certificate at the end.
Common questions
Do I need planning permission for an air conditioning unit on my house?
In England, often not. Since 29 May 2025 air-to-air heat pumps can be fitted under permitted development if they meet the size, position and noise conditions and are not used solely for cooling. Listed homes, some conservation areas and Article 4 areas still need permission.
Can I fit air conditioning myself?
Not a split system. Connecting the refrigerant circuit must be done by an F-gas qualified engineer working for a certified company. Portable units that plug in and vent through a window need no installer.
What is an F-gas engineer?
An engineer qualified to handle fluorinated gas refrigerants used in air conditioning and heat pumps. Their company must hold F-gas certification from an approved certification body.
Home air conditioning. Describe your job and a verified local tradesperson comes back with a priced quote you can accept online.